Chemical Safety Board finds explosion was caused by cooling system failure in a runaway reaction

Dorothy Lozowski

The massive December 2007 explosion and fire at T2 Laboratories in Jacksonville, Fla. was caused by a runaway chemical reaction that likely resulted from an inadequate reactor cooling system, investigators from the U.S. Chemical Safety Board (CSB; www.csb.gov) said in a final draft report released today. Concluding that T2 did not recognize all of the potential hazards of the process for making a gasoline additive, the report calls for improving the education of chemical engineering students on reactive chemical hazards. The explosion and fire on December 19, 2007, killed four T2 employees and injured four others. In addition, 28 people working at nearby businesses were injured when building walls and windows blew in. The blast sent debris up to a mile away and damaged buildings within a quarter-mile of the facility. “This is one of the largest reactive chemical accidents the CSB has investigated,” said chairman John Bresland. “We hope our findings once again call attention to the need for companies to be aware of how to control reactive chemical hazards.” In 2002 the CSB completed a study of reactive chemical hazards, which identified 167 accidents over a two-decade period and made recommendations to improve reactive chemical safety.

The draft report on the T2 Laboratories explosion calls on the American Institute of Chemical Engineers (AIChE) and the Accreditation Board for Engineering and Technology (ABET) to work together to include reactive chemical education in baccalaureate chemical engineering curricula across the country. The CSB found that although the two owners of the company had undergraduate degrees in chemistry and chemical engineering, they were nonetheless likely unaware of the potential or the consequences of a runaway chemical reaction. The CSB noted that most baccalaureate chemical engineering curricula in the U.S. do not specifically address reactive hazard recognition or management. Chairman Bresland said, “It’s important that chemical engineers recognize and are aware of the proper management of reactive hazards.” Investigation supervisor Robert Hall, said, “Our recommendations aim to address the gap in the chemical engineering curriculum. If future chemical engineers are given the proper educational tools, they will be able to more fully comprehend the hazards that exist during a chemical manufacturing process.”

The CSB also today released a 3-D computer animation depicting the events that led to the accident. Following approval of the report, the CSB plans to release a new nine-minute safety video, “Runaway: Explosion at T2 Laboratories,” containing the 3-D computer animation and a description of the causes, consequences, lessons, and recommendations resulting from the accident.

The accident occurred during T2’s production of MCMT, a gasoline additive, which the company manufactured in batches using a 2,500-gal reactor. On the day of the accident T2 was producing its 175th batch of the chemical when operators reported a cooling problem. Mr. Hall said, “Despite a number of near-misses during earlier production efforts, T2 failed to recognize the underlying runaway reaction hazard associated with its manufacturing process.” Chemical testing by the CSB found that the recipe used by T2 created two exothermic, or heat-producing, reactions; the first was an intended part of producing MCMT but the second, undesired reaction occurred if the temperature went above 390ºF, slightly higher than the normal production temperature.  The cooling system likely malfunctioned due to a blockage in the water supply piping or a valve failure. The temperature and pressure inside the reactor began to rise uncontrollably in a runaway chemical reaction. At 1:33 pm, approximately ten minutes after the initial cooling problem was reported, the reactor burst and its contents exploded.

The CSB is an independent federal agency charged with investigating industrial chemical accidents. The agency’s board members are appointed by the President and confirmed by the Senate. CSB investigations look into all aspects of chemical accidents, including physical causes such as equipment failure as well as inadequacies in regulations, industry standards, and safety management systems.

 

Add a Comment

Name:
Email:
Comments:

Please enter the letters or numbers you see in the image. (refresh)
 
 

Related Stories

LinkedIn Groups

Our LinkedIn group is now over 33,000 members strong!

  1. Join other CPI professionals from all over the globe and share best practices, expertise, concerns and more.
  2. Provide feedback to Chemical Engineering Editors


Current members represent Worley Parsons, DuPont, SABIC, Fluor, Air Products, LyondellBasell, Nalco, Dow Chemical, Dow Corning, BASF, Jacobs Engineering, ExxonMobil, Shell, Chevron and more.

Join Now



We also offer the following subgroup for more targeted discussions:

Tools
Search the Buyers' Guide

Plant Cost Index

Facts at Your Fingertips (archive)

Ask the Experts

Back Issues
X
To access this area, please log in or create an account.
Username:
Password:
Forgot your password?
Request it now.
Processing...
Live chat by BoldChat