<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Chemical Engineering &#187; Heat Transfer</title>
	<atom:link href="http://www.chemengonline.com/category/heat-transfer/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.chemengonline.com</link>
	<description>Chemical Engineering essentials for the global chemical processing industries (CPI)</description>
	<lastBuildDate>Tue, 11 Jul 2017 18:15:47 +0000</lastBuildDate>
	<language>en-US</language>
		<sy:updatePeriod>hourly</sy:updatePeriod>
		<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=4.0</generator>
	<item>
		<title>Focus on Heating and Cooling Systems</title>
		<link>http://www.chemengonline.com/focus-heating-cooling-systems/</link>
		<comments>http://www.chemengonline.com/focus-heating-cooling-systems/#comments</comments>
		<pubDate>Thu, 01 Jun 2017 04:00:00 +0000</pubDate>
		<dc:creator><![CDATA[Chemical Engineering]]></dc:creator>
				<category><![CDATA[Heat Transfer]]></category>
		<category><![CDATA[cooling systems]]></category>
		<category><![CDATA[heat exchange]]></category>
		<category><![CDATA[heat exchanger]]></category>
		<category><![CDATA[heat transfer]]></category>

		<guid isPermaLink="false">http://www.chemengonline.com/?p=143917</guid>
		<description><![CDATA[<p>Guard against gasket wear in plate heat exchangers Gaskets used in plate heat exchangers (photo) wear over time, due to natural aging, and the effect of temperature, pressure and stress that results from</p>
<p>The post <a rel="nofollow" href="http://www.chemengonline.com/focus-heating-cooling-systems/">Focus on Heating and Cooling Systems</a> appeared first on <a rel="nofollow" href="http://www.chemengonline.com">Chemical Engineering</a>.</p>
]]></description>
		<wfw:commentRss>http://www.chemengonline.com/focus-heating-cooling-systems/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Special Flange Joints Used in Floating-Head Shell-and-Tube Heat Exchangers</title>
		<link>http://www.chemengonline.com/special-flange-joints-used-in-floating-head-shell-and-tube-heat-exchangers/</link>
		<comments>http://www.chemengonline.com/special-flange-joints-used-in-floating-head-shell-and-tube-heat-exchangers/#comments</comments>
		<pubDate>Wed, 01 Feb 2017 00:00:00 +0000</pubDate>
		<dc:creator><![CDATA[Chemical Engineering]]></dc:creator>
				<category><![CDATA[Heat Transfer]]></category>
		<category><![CDATA[Heat Exchangers]]></category>

		<guid isPermaLink="false">http://www.chemengonline.com/?p=136668</guid>
		<description><![CDATA[<p>Single-pass, floating-head heat exchangers are common in certain process operations, but they often use flange joints that are not covered in existing design codes. Design details, advantages and disadvantages</p>
<p>The post <a rel="nofollow" href="http://www.chemengonline.com/special-flange-joints-used-in-floating-head-shell-and-tube-heat-exchangers/">Special Flange Joints Used in Floating-Head Shell-and-Tube Heat Exchangers</a> appeared first on <a rel="nofollow" href="http://www.chemengonline.com">Chemical Engineering</a>.</p>
]]></description>
		<wfw:commentRss>http://www.chemengonline.com/special-flange-joints-used-in-floating-head-shell-and-tube-heat-exchangers/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Heat Exchanger Standards for Shell-and-Tube Equipment</title>
		<link>http://www.chemengonline.com/heat-exchanger-standards-for-shell-and-tube-equipment/</link>
		<comments>http://www.chemengonline.com/heat-exchanger-standards-for-shell-and-tube-equipment/#comments</comments>
		<pubDate>Wed, 01 Feb 2017 00:00:00 +0000</pubDate>
		<dc:creator><![CDATA[Chemical Engineering]]></dc:creator>
				<category><![CDATA[Heat Transfer]]></category>
		<category><![CDATA[Heat Exchangers]]></category>

		<guid isPermaLink="false">http://www.chemengonline.com/?p=136666</guid>
		<description><![CDATA[<p>Reliable operation of shell-and-tube heat exchangers begins with an appropriate standard. This article provides an overview of those that are applicable Shell-and-tube heat exchangers are the backbone of the</p>
<p>The post <a rel="nofollow" href="http://www.chemengonline.com/heat-exchanger-standards-for-shell-and-tube-equipment/">Heat Exchanger Standards for Shell-and-Tube Equipment</a> appeared first on <a rel="nofollow" href="http://www.chemengonline.com">Chemical Engineering</a>.</p>
]]></description>
		<wfw:commentRss>http://www.chemengonline.com/heat-exchanger-standards-for-shell-and-tube-equipment/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Heat Transfer in Wiped Film Evaporators</title>
		<link>http://www.chemengonline.com/heat-transfer-wiped-film-evaporators/</link>
		<comments>http://www.chemengonline.com/heat-transfer-wiped-film-evaporators/#comments</comments>
		<pubDate>Tue, 01 Nov 2016 00:00:00 +0000</pubDate>
		<dc:creator><![CDATA[Chemical Engineering]]></dc:creator>
				<category><![CDATA[Heat Transfer]]></category>
		<category><![CDATA[Evaporation]]></category>
		<category><![CDATA[evaporators]]></category>
		<category><![CDATA[heat transfer]]></category>
		<category><![CDATA[simulation]]></category>

		<guid isPermaLink="false">http://www.chemengonline.com/?p=131386</guid>
		<description><![CDATA[<p>Simulations demonstrate the complex, changing properties of materials within the evaporator. Such information can help in both designing and selecting the proper evaporator A wiped film or agitated thin-film</p>
<p>The post <a rel="nofollow" href="http://www.chemengonline.com/heat-transfer-wiped-film-evaporators/">Heat Transfer in Wiped Film Evaporators</a> appeared first on <a rel="nofollow" href="http://www.chemengonline.com">Chemical Engineering</a>.</p>
]]></description>
		<wfw:commentRss>http://www.chemengonline.com/heat-transfer-wiped-film-evaporators/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>New Ways to Deal With Old Heat-Transfer Issues</title>
		<link>http://www.chemengonline.com/new-ways-deal-old-heat-transfer-issues/</link>
		<comments>http://www.chemengonline.com/new-ways-deal-old-heat-transfer-issues/#comments</comments>
		<pubDate>Wed, 01 Jun 2016 00:00:00 +0000</pubDate>
		<dc:creator><![CDATA[Chemical Engineering]]></dc:creator>
				<category><![CDATA[Heat Transfer]]></category>
		<category><![CDATA[Heat Exchangers]]></category>

		<guid isPermaLink="false">http://www.chemengonline.com/new-ways-deal-old-heat-transfer-issues/</guid>
		<description><![CDATA[<p>Chemical processors are no strangers to heat exchanger problems, such as corrosion, fouling and thermal expansion, which interfere with reliability of the units and adversely affect process uptime. Because</p>
<p>The post <a rel="nofollow" href="http://www.chemengonline.com/new-ways-deal-old-heat-transfer-issues/">New Ways to Deal With Old Heat-Transfer Issues</a> appeared first on <a rel="nofollow" href="http://www.chemengonline.com">Chemical Engineering</a>.</p>
]]></description>
		<wfw:commentRss>http://www.chemengonline.com/new-ways-deal-old-heat-transfer-issues/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Insulating Heat-Transfer-Fluid Piping</title>
		<link>http://www.chemengonline.com/insulating-heat-transfer-fluid-piping/</link>
		<comments>http://www.chemengonline.com/insulating-heat-transfer-fluid-piping/#comments</comments>
		<pubDate>Sun, 01 May 2016 00:00:00 +0000</pubDate>
		<dc:creator><![CDATA[Chemical Engineering]]></dc:creator>
				<category><![CDATA[Heat Transfer]]></category>

		<guid isPermaLink="false">http://www.chemengonline.com/insulating-heat-transfer-fluid-piping/</guid>
		<description><![CDATA[<p>Department Editor: Scott Jenkins Heat-transfer-fluid (HTF) system piping is insulated to reduce heat loss and prevent worker contact with hot surfaces. Insulated piping minimizes the effects of changes in</p>
<p>The post <a rel="nofollow" href="http://www.chemengonline.com/insulating-heat-transfer-fluid-piping/">Insulating Heat-Transfer-Fluid Piping</a> appeared first on <a rel="nofollow" href="http://www.chemengonline.com">Chemical Engineering</a>.</p>
]]></description>
		<wfw:commentRss>http://www.chemengonline.com/insulating-heat-transfer-fluid-piping/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Bio-based heat-transfer fluid for solar-thermal applications</title>
		<link>http://www.chemengonline.com/bio-based-heat-transfer-fluid-solar-thermal-applications/</link>
		<comments>http://www.chemengonline.com/bio-based-heat-transfer-fluid-solar-thermal-applications/#comments</comments>
		<pubDate>Fri, 01 Apr 2016 00:00:00 +0000</pubDate>
		<dc:creator><![CDATA[Chemical Engineering]]></dc:creator>
				<category><![CDATA[Heat Transfer]]></category>
		<category><![CDATA[heat transfer fluid]]></category>
		<category><![CDATA[solar energy]]></category>

		<guid isPermaLink="false">http://www.chemengonline.com/bio-based-heat-transfer-fluid-solar-thermal-applications/</guid>
		<description><![CDATA[<p>A recently introduced heat-transfer fluid is made from corn sugar, rather than from petroleum. Known as So-Blu, the fluid was developed through a joint effort of Dupont Tate &#38; Lyle BioProducts (Loudon</p>
<p>The post <a rel="nofollow" href="http://www.chemengonline.com/bio-based-heat-transfer-fluid-solar-thermal-applications/">Bio-based heat-transfer fluid for solar-thermal applications</a> appeared first on <a rel="nofollow" href="http://www.chemengonline.com">Chemical Engineering</a>.</p>
]]></description>
		<wfw:commentRss>http://www.chemengonline.com/bio-based-heat-transfer-fluid-solar-thermal-applications/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>This gas-standard generator allows for automatic control</title>
		<link>http://www.chemengonline.com/gas-standard-generator-allows-automatic-control/</link>
		<comments>http://www.chemengonline.com/gas-standard-generator-allows-automatic-control/#comments</comments>
		<pubDate>Tue, 01 Mar 2016 00:00:00 +0000</pubDate>
		<dc:creator><![CDATA[Chemical Engineering]]></dc:creator>
				<category><![CDATA[Heat Transfer]]></category>
		<category><![CDATA[gas calibration]]></category>

		<guid isPermaLink="false">http://www.chemengonline.com/gas-standard-generator-allows-automatic-control/</guid>
		<description><![CDATA[<p>The 491Flex Calibration Gas Standards Generator (photo) is an update of the 491M manual system, retaining the modular construction and expandability of the previous model, but replacing the analog</p>
<p>The post <a rel="nofollow" href="http://www.chemengonline.com/gas-standard-generator-allows-automatic-control/">This gas-standard generator allows for automatic control</a> appeared first on <a rel="nofollow" href="http://www.chemengonline.com">Chemical Engineering</a>.</p>
]]></description>
		<wfw:commentRss>http://www.chemengonline.com/gas-standard-generator-allows-automatic-control/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Shell-and-Tube Heat Exchangers: The Design Cycle</title>
		<link>http://www.chemengonline.com/shell-tube-heat-exchangers-design-cycle/</link>
		<comments>http://www.chemengonline.com/shell-tube-heat-exchangers-design-cycle/#comments</comments>
		<pubDate>Tue, 01 Mar 2016 00:00:00 +0000</pubDate>
		<dc:creator><![CDATA[Chemical Engineering]]></dc:creator>
				<category><![CDATA[Heat Transfer]]></category>
		<category><![CDATA[Heat Exchangers]]></category>
		<category><![CDATA[shell and tube heat exchangers]]></category>

		<guid isPermaLink="false">http://www.chemengonline.com/shell-tube-heat-exchangers-design-cycle/</guid>
		<description><![CDATA[<p>Saheli Bhattacharyya and Siddhartha Mukherjee Air Liquide Global E&#38;C Solutions India Shell-and-tube heat exchangers are among the most commonly used equipment in the chemical process industries (CPI)</p>
<p>The post <a rel="nofollow" href="http://www.chemengonline.com/shell-tube-heat-exchangers-design-cycle/">Shell-and-Tube Heat Exchangers: The Design Cycle</a> appeared first on <a rel="nofollow" href="http://www.chemengonline.com">Chemical Engineering</a>.</p>
]]></description>
		<wfw:commentRss>http://www.chemengonline.com/shell-tube-heat-exchangers-design-cycle/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Superheater Problems in Steam Generators</title>
		<link>http://www.chemengonline.com/superheater-problems-steam-generators/</link>
		<comments>http://www.chemengonline.com/superheater-problems-steam-generators/#comments</comments>
		<pubDate>Mon, 01 Feb 2016 00:00:00 +0000</pubDate>
		<dc:creator><![CDATA[Chemical Engineering]]></dc:creator>
				<category><![CDATA[Heat Transfer]]></category>
		<category><![CDATA[Boilers]]></category>
		<category><![CDATA[steam generation]]></category>

		<guid isPermaLink="false">http://www.chemengonline.com/superheater-problems-steam-generators/</guid>
		<description><![CDATA[<p>Viswanathan Ganapathy Boiler Consultant Oil- and gas-fired package steam generators (or boilers; Figure 1) are used in chemical plants, power plants, petroleum refineries and in cogeneration plants to generate</p>
<p>The post <a rel="nofollow" href="http://www.chemengonline.com/superheater-problems-steam-generators/">Superheater Problems in Steam Generators</a> appeared first on <a rel="nofollow" href="http://www.chemengonline.com">Chemical Engineering</a>.</p>
]]></description>
		<wfw:commentRss>http://www.chemengonline.com/superheater-problems-steam-generators/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
