Fugitive emissions — defined as unintended releases of volatile organic compounds (VOCs) from process equipment to the atmosphere — have been a long-standing issue in the chemical process industries (CPI). Valves and pumps are two of the leading sources. With valves, the primary cause of fugitive emissions is failure of packing seals and gaskets, which are designed to maintain a seal between the valve bonnet and stem. This column describes potential solutions to address valve-packing failures.
Two of the most common ways to prevent fugitive emissions from valves are using live-loaded packing and bellows seals. Live-loaded packing, a method where a compressive force is applied to the packing material so that it tightly seals against the interior of the valve bonnet, can be paired with nearly any valve configuration to achieve very low leakage rates. Bellows seals are only available with sliding stem valves, but provide even lower leakage rates — near zero in most cases.
Seal selection
Seal-system selection is based on the specific requirements of the application, but some some general guidelines apply in most cases. Solutions emitting no more than either 500 parts per million by volume (ppmv) or 100 ppmv, depending on the location of the facility, are usually required. Live-loaded packing is sufficient in most cases to achieve compliance, but bellows seals are often used to further reduce (or even eliminate) emissions.
End users typically work with a valve vendor to determine the best solution for an application by balancing price and performance. Live-loaded packing is less expensive than, but not as effective as, bellows seals. When process media is lethal, volatile or radioactive, bellows seals are the industry standard because they prevent the stem and packing from coming into contact with the process media. The result is leakage rates down to 1 × 10–6 cm3/s of helium.
Materials
When live-loaded packing is used, the material of choice is typically either polytetrafluoroethylene (PTFE) or graphite. PTFE offers near-universal chemical compatibility with many types of process media. It also provides very low friction, which allows for smaller sizing of actuators, but it has process-media temperature limitations. Typically, vendors use 450°F as the upper limit for PTFE packing.
Similar to PTFE, graphite is compatible with most process media, but graphite-based packing systems can be used in applications for VOCs where the process media temperature is up to about 750°F. Graphite also has the additional upside of being inherently fire-safe.
Some packing systems provide capabilities of both PTFE and graphite, making them the best fit in certain applications. This is achieved by using a layer of graphite packing rings closer to the process media, and a layer of PTFE rings farther away from the process media. These systems provide low friction and emissions, and in some cases, an API 589 fire-tested solution, for operation at process media temperatures up to 450°F.
Leak testing
For all types of valves, testing is required to ensure effectiveness in operation (Figures 1 and 2).

FIGURE 1. Testing for requirements for ISO 15848-1 include compliance with several combinations of leakage classes and thermal and mechanical cycles

FIGURE 2. Leakage is recorded as a leakage rate per measured valve stem size
International Organization for Standardization (ISO) 15848 applies to both control and isolation valves, and has two components. A vendor test (ISO 15848-1) proves the capabilities of a technology, and a production test (ISO 15848-2) proves the production equipment meets the requirements while in operation. The testing requirements for ISO 15848-1 include compliance with several combinations of leakage classes, thermal cycles and mechanical cycles to qualify for certification.
ISO 15848-1 specifies use of either the vacuum or flushing “total leakage” measurement methods described in Annex A of the standard. Leakage is recorded as a leakage rate per measured stem size. ISO 15848-1 states there is no correlation intended between the leakage tightness classes, whether the test fluid is helium or methane. The other popular method to detect leakage is Method 21 from the U.S. EPA, which is also specified in ANSI/FCI 91-1. This method stipulates leakages between 500 and 100 ppmv.
Performing these leakage measurements in the field is both costly and time consuming, as it requires sophisticated listening devices operated by a skilled technician to detect leaks. But if a company has demonstrated success with detecting and correcting issues, monitoring-period extensions of up to one year, instead of every three to six months, can be implemented. For frequent offenders, monthly measurements need to be taken. Specifically, facility personnel must prove that no more than 0.5% of its total valve population has issues with stem or shaft leakages if they are to extend monitoring periods.
Editor’s notes: 1) The content for this edition of “Facts at your Fingertips” was developed by Andrew Prusha, director – Chemical Process Industries, Emerson; 2) For more on valve emissions, see: www.emerson.com/documents/automation/control-valve-handbook-en-3661206.pdf.